Your design has been saved as a draft, please login to save your artwork to your account for further editing or purchasing.
Options | Price |
---|
Parameter
| PM9200 |
Bandwidth
| DC,0.5Hz~2KHz |
Input model
| Voltage and Current are floating input |
Accuracy
| (0.2%) |
Display update
| Display refresh cycle 0.1s~5s |
Line filtering
| cut-off frequency 500Hz |
A/D Converter
| sampling period 70μS,24bits,voltage and current simultaneous sampling |
Input Impedance
| Voltage input impedance is 2MΩ, current input impedance is 0.5Ω, High-grade is 4mΩ. The input impedance of the input terminal of External sensor signal Changes according to the change of input voltage.10V: 100kΩ,2V: 20 kΩ. |
Zero mode
| Calibrate the zero point each time when the range is changed or the measurement mode is changed |
Measurement mode
| RMS VOLTAGE MEAN AC DC |
The power consumption
| < 10VA |
Power supply of meter
| AC 100V~240V 45~440Hz DC 100V~300V |
Communication Interface
| USB,RS-232/485(standard), Ethernet(optional) |
Parameter
| Measuring Range
|
Error |
Min. resolution
|
Voltage
| (0.5~600)V
|
DC ±(read 0.1% + range 0.2% )
0.5 Hz ≤ f< 45 Hz ±(read 0.1% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1 % ) 66 Hz < f ≤ 1 kHz ±(read 0.1% + range 0.2 % ) 1 k Hz < f ≤ 2 kHz ±(read 0.15% + range 0.3% ) |
0.001V
|
Current
| 0.05mA~45A
| 0.001A
| |
Active power
| U*I*PF | DC ±(read 0.1% + range 0.2% )
0.5 Hz ≤ f< 45 Hz ±(read 0.3% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1 % ) 66 Hz < f ≤ 1 kHz ±(read 0.2% + range 0.2 % ) 1 k Hz < f ≤ 2 kHz ±(read 0.2% + range 0.3 % ) | 0.001mW
|
Power factor | 0.01~1 | 0.5 Hz ≤ f≤ 66 Hz ±0.01
66 Hz < f ≤ 1 kHz ±0.02 1 k Hz < f ≤ 2 kHz ±0.05 | 0.001 |
Frequency
| 0.5Hz~2KHz
| 0.1% | 0.001Hz
|
Electric energy accumulation
| 0~999999MWh 0~-99999MWh | DC ±(read 0.1% + range 0.2% )
0.5 Hz ≤ f< 45 Hz ±(read 0.3% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1% ) 66 Hz < f ≤ 1 kHz ±(read 0.2% + range 0.2% ) 1 k Hz < f ≤ 2 kHz ±(read 0.2% + range 0.3% ) | 0.0001mWh |
Total ah | 0~999999MAh 0~-99999MAh | DC ±(read 0.1% + range 0.2% )
0.5 Hz ≤ f< 45 Hz ±(read 0.1% + range 0.2% ) 45 Hz ≤ f ≤ 66 Hz ±(read 0.1% + range 0.1% ) 66 Hz < f ≤ 1 kHz ±(read 0.1% + range 0.2% ) 1 k Hz < f ≤ 2 kHz ±(read 0.15%+ range 0.3% ) | 0.0001mAh |
Electric energy timing
| 99999h
| ± 2s/H | 1s
|
Harmonic | 1~50times
Accuracy: B class IEC61000-4-7 | Maximum times of fundamental frequency analysis 10Hz~65Hz 50 65Hz~100Hz 32 100Hz~200Hz 16 200Hz~400Hz 8 | 0.01 |